Kemppi FreshAir Flow Control unit Bedienungsanleitung Seite 9

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 18
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 8
EN
9© Kemppi Oy / 1309
The unit ensures a constant supply of air. The microprocessor inside the unit
automatically regulates the motor speed to compensate the lter clogging
and the battery state.
If the microprocessor cannot maintain the adjusted airow, an acoustic
alarm signal can be heard and the LED diodes display RED in colour. If
possible, the microprocessor automatically reduces the airow to the next
lower level.
When the airow falls below the minimum level, the alarm intensies. Then
the user must stop working at once and change the lter or recharge/
change the battery.
!
To check the alarm function, perform the air ow test as explained in section
4.2: "Air ow test".
4.4 Checking the battery state
Press and hold the left button (–) for more than 1 second. The more red
coloured LED diodes come on, the higher the remaining battery capacity is.
> 1 s
9© Kemppi Oy / 1309
Seitenansicht 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 17 18

Kommentare zu diesen Handbüchern

Keine Kommentare